Mining Ventilation Fan
【 Capacity 】5.5kw-132kw
【Application】Mining ventilation
【Our Services】
- ♦Online visit factory
- ♦ Mining ventilation plan design,
- ♦ draw the layout,
- ♦ Factory test before delivery,
- ♦ online video teaching,
- ♦ one year warranty.
- Introduction&Model
what’s a mining ventilation fan :Mine fans are mainly used for mine ventilation,It can used in coal mines with gas or coal dust explosion risks. It is also suitable for metal mines, chemical mines, tunnels and other factories and mines that use fans.
Application & Type:
Use environment: the temperature of the conveying medium does not exceed 40 ℃, the humidity does not exceed 95 ±% 3 (25 ℃), and there is no corrosive gas.
Main Features: The driving motor of the fan and the fan casing are combined into one, the mounting plate for installing the motor and the heat sink and fin of the motor are eliminated,which make the structure is more compact and the flow channel is more smooth. Therefore, the noise is lower and the operating efficiency is higher.
- Technical Specifications
FBDY MODEL MINE VENTILATOR FAN Technical Characteristics:
1. High-performance blade aerodynamic design grade type noise reduction measures etc.
2. The rings and fixed feet are convenient and beautiful.
3. High full (static) pressure efficiency wide range of high-efficiency use with an ideal energy saving effect. Compared with the same model the full (static) pressure efficiency is improved by about 2 percentage points.
4. Low noise: fans with No. 6.0 and below are less than 85 fans with No. 6.0 and above are less than 95.
No. | Motor Power (KW) | Air Volume (m3/min) | full pressure(Pa) | Maximum full pressure efficiency(%) | compared to a sound levels[dB(A)] |
No3.5 | 2×1.1 | 153~76 | 250~1500 | ≥75 | ≤30 |
3×1.1 | 153~76 | 350~2100 | |||
4×1.1 | 153~76 | 450~2700 | |||
No4 | 2×2.2 | 220~113 | 300~1800 | ≥75 | ≤30 |
3×2.2 | 220~113 | 420~2520 | |||
4×2.2 | 220~113 | 540~3240 | |||
No4.5 | 2×4 | 220~150 | 300~2300 | ≥75 | ≤30 |
3×4 | 220~150 | 420~3220 | |||
4×4 | 220~150 | 540~4140 | |||
No4.5 | 2×5.5 | 240~160 | 320~3100 | ≥75 | ≤30 |
3×5.5 | 240~160 | 440~4340 | |||
4×5.5 | 240~160 | 580~5580 | |||
No5.0 | 2×7.5 | 300~180 | 340~3500 | ≥75 | ≤30 |
3×7.5 | 300~180 | 480~4900 | |||
4×7.5 | 300~180 | 610~6300 | |||
No5.6 | 2×11 | 400~200 | 350~4000 | ≥80 | ≤25 |
3×11 | 400~200 | ||||
4×11 | 400~200 | 630~7200 | |||
No6.0 | 2×15 | 450~250 | 440~5100 | ≥80 | ≤25 |
3×15 | 450~250 | 620~7100 | |||
4×15 | 450~250 | 790~9200 | |||
No6.0 | 2×18.5 | 500~250 | 450~5500 | ≥80 | ≤25 |
3×18.5 | 500~250 | 630~7700 | |||
4×18.5 | 500~250 | 810~9900 | |||
No6.0 | 2×22 | 550~250 | 450~6000 | ≥80 | ≤25 |
3×22 | 550~250 | 630~8400 | |||
4×22 | 550~250 | 810~10800 | |||
No6.3 | 2×30 | 630~260 | 460~6300 | ≥80 | ≤25 |
3×30 | 630~260 | 640~8820 | |||
4×30 | 630~260 | 830~11340 | |||
No6.7 | 2×37 | 730~410 | 920~6500 | ≥80 | ≤25 |
3×37 | 730~410 | 1200~9000 | |||
4×37 | 730~410 | 1480~1160 | |||
No7.1 | 2×45 | 820~550 | 1480~6650 | ≥80 | ≤25 |
3×45 | 820~550 | 1480~9130 | |||
4×45 | 820~550 | 1850~11740 | |||
No7.5 | 2×55 | 980~630 | 1850~6800 | ≥80 | ≤25 |
3×55 | 980~630 | 1850~9240 | |||
4×55 | 980~630 | 2200~11880 | |||
No8.0 | 2×75 | 1250~680 | 2200~7100 | ≥80 | ≤25 |
FBCZ MINE VENTILATOR FAN Technical Parameters
Series name | Machine number | Motor model | Motor Power(kw) | High-efficiency area | Compared to A sound levels db(A) | |
Air volume(m2/s) | Static pressure(pa) | ≤35 | ||||
FBCZ-4-No n=1450r/min | 8 | YBF132S-4 | 5.5 | 3.6-8.9 | 110-580 | ≤35 |
9 | YBF160M-4 | 11 | 4.6-12.8 | 130-710 | ≤38 | |
10 | YBF160L-4 | 15 | 6.7-17 | 150-920 | ≤38 | |
11 | YBF200L1-4 | 30 | 9.2-23.3 | 190-1100 | ≤38 | |
12 | YBF225M-4 | 45 | 11-31 | 220-1350 | ≤38 | |
13 | YBF250M-4 | 55 | 13.8-38 | 250-1600 | ≤38 | |
FBCZ-6-N on=980r/min | 10 | YBF160M-6 | 7.5 | *4-12 | 75-400 | ≤38 |
11 | YBF160L-6 | 11 | *6-15 | 85-510 | ≤38 | |
12 | YBF180L-6 | 15 | *8-21 | 95-590 | ≤38 | |
13 | YBF200L2-6 | 22 | *11-27 | 115-690 | ≤38 | |
14 | YBF225M-6 | 30 | 12.5-33 | 145-800 | ≤38 | |
15 | YBF280S-6 | 45 | 15-40 | 170-900 | ≤38 | |
16 | YBF280M-6 | 55 | 20-48 | 195-1100 | ≤38 | |
17 | YBF315S-6 | 75 | 21-57 | 205-1200 | ≤38 | |
18 | YBF315L1-6 | 110 | 26-70 | 215-1350 | ≤38 | |
19 | YBF315L2-6 | 132 | 31-80 | 230-1550 | ≤38 |
- Questions before inquiry
Whats the three phase voltage in your country?
Is that applied in coal mines or metal mines?
- What’s the air volume and air pressure?
- Cases
- Contact us now for more details!
Mining Machine
Cases
- High-Quality Mining Support Materials ExportDecember 11, 2024 - 5:51 pm
- Mining Equipment Exporting to OverseasDecember 9, 2024 - 4:25 pm
- 2.5 Ton Battery Electric Locomotives Prepared for Overseas DeliveryNovember 20, 2024 - 5:54 pm
- A batch of mining electric dump trucks sent to overseasSeptember 15, 2024 - 1:52 am
- 10 Ton Trolley Wire Locomotives Loaded for ExportAugust 16, 2024 - 8:14 am
- Export of 10 ton trolley wire locomotivesAugust 2, 2024 - 6:16 am
Contact us
HNYT EQUIPMENT
We could provide live video to show your our factory! Please directly send us the inquiry to our Email or contact us in Whatsapp.
Tel: +86-731-58528855
Mob: +8617773243529
Email: [email protected]
Add: No. 48, Liancheng avenue, Jiuhua Industrial Park, Jiuhua Economic Zone, Xiangtan City, Hunan, P.R,China